CHNS/O Analyzer | Allanalysis
Allanalysis
...Precision + Speed
Request Call Back
← Back to Articles

Analytical

CHNS/O Analyzer

The ELEMENTRAC CS-i elemental analyzer measures carbon and sulfur concentrations in solid samples by melting them in a pure oxygen atmosphere within an induction furnace. Sulfur oxidizes to SO₂ and carbon to CO and CO₂. A lance directs oxygen precisely into the crucible to ensure complete combustion and prevent sample loss, especially for dusty materials. Typical sample sizes range from 50 to 1000 mg, and accelerators like tungsten are added. Sample shape does not affect results. The process is automated via ELEMENTS software, and results are available within 45–60 seconds. The ELEMENTRAC CS-i elemental analyzer measures carbon and sulfur concentrations in solid samples by melting them in a pure oxygen atmosphere within an induction furnace. Sulfur oxidizes to SO₂ and carbon to CO and CO₂. A lance directs oxygen precisely into the crucible to ensure complete combustion and prevent sample loss, especially for dusty materials. Typical sample sizes range from 50 to 1000 mg, and accelerators like tungsten are added. Sample shape does not affect results. The process is automated via ELEMENTS software, and results are available within 45–60 seconds.

By Allschoolabs · August 2, 2025 · 78 views

Add Article Run Test Sell Product
CHNS/O Analyzer
The elemental analyzer ELEMENTRAC CS-i was used to measures the carbon and sulfur concentration In the induction furnace of the elemental analyzer the sample is melted in a pure oxygen atmosphere, causing sulfur to react to sulfur dioxide (SO2) and carbon to a mixture of carbon monoxide (CO) and carbon dioxide (CO2).Individual control of the oxygen supply during inductive combustionA lance flushes the entire oxygen flow to the center of the crucible to ensure complete oxidation of the carbon and sulfur contained in the sample (solid samples)Oxygen flow is supplied through the combustion chamber to avoid swirling and loss of sample material (dusty samples)Sample volumes of 50 mg to 1000 mg are typical for C/S analysis. The sample is weighed in a ceramic crucible and accelerators like tungsten are added. The geometry of the sample (e. g. wire, powder, pin etc.) is not essential for a reliable analysis. The ceramic crucible is then placed on the pedestal and the analysis is started via the ELEMENTS software. The software controls all subsequent steps like combustion and evaluation.45-60 seconds after the analysis has started, the measured carbon and sulfur concentrations are available for export as a report

Comments & Questions (0)

Related Articles

Why Blood Tests Are Important for Preventive Healthcare and Early Detection
Why Blood Tests Are Important for Preventive Healthcare and Early Detection

Blood tests can support early detection by identifying changes in bloo…

SEM-EDS Analysis: How Researchers Identify Elements on Material Surfaces
SEM-EDS Analysis: How Researchers Identify Elements on Material Surfaces

SEM-EDS combines scanning electron microscopy with energy-dispersive X…

How to Read Common Blood Test Results Without Getting Confused by the Numbers
How to Read Common Blood Test Results Without Getting Confused by the Numbers

To read common blood test results, check the test name, measured value…

Malaria Testing in Nigeria: When to Test and Which Laboratory Tests Are Used
Malaria Testing in Nigeria: When to Test and Which Laboratory Tests Are Used

Malaria testing in Nigeria is mainly performed using a rapid diagnosti…

Free Research

Research Journals

Access 25,000,000 scientific papers, medical journals and analytical research.

Open Journal

Need a lab test?

Browse verified tests and book directly from Allanalysis.

Browse Tests
Need help?Chat with us or
or contact us
Chat now